1. EDIUSWORLD.COM TOP
  2. Support
  3. Faq
  4. "Synchronization of project and database" appears while loading a project

“Synchronization of project and database” appears while loading a project

  • Operation
“Synchronization of project and database” appears while loading a project

FAQ ID:000026081 | Date:2024/05/16

"Synchronization of project and database" appears while loading a project

Issue summary
When loading a project that has not been synchronized to the database, registration of used assets to the database also runs.
In previous build (earlier than 11.11.14439), synchronization timeout occurred and the message “This project was synchronized with the database.” appears everytime loading a project. The message will appear if sync timeout occurs.

 

What improvement is implemented?
From 11.11.14439, EDIUS synchronizes with database up to 100 clips per one time – if selected project has more clips, sync process runs in 100 clips unit. Furthermore, if this process fails, EDIUS retries sync process in 50 clips unit. Appearing below message means that retrying sync process failed.

 

Troubleshooting
If the message appears and you have EDIUS X or earlier, try below troubleshooting procedure:

1) Load same project in EDIUS X or earlier then unregister clips to be less than 1000.

2) Save it via ‘Save as’ menu.

3) Load it in EDIUS 11.


MENU

About EDIUS
License
Specification
Installation
Starting-up
View
Project Settings
Clip
Import / Capture / Data migration
Operation
Effect
Title
Audio
Export
Hardware
Others
User Settings
eID (EDIUS ID)
Environment Settings
Editing Configuration
Disc Burner
EDIUS All
EDIUS Elite
EDIUS Elite 7
EDIUS Express
EDIUS Neo 3.5
EDIUS Pro 6.5
EDIUS Pro 7
EDIUS Pro 8
EDIUS Pro 9
EDIUS Workgroup 8
EDIUS Workgroup 9
EDIUS X Pro
EDIUS X Workgroup
FAQ Archives
Rendering
Settings
Subscription